MIL-S-49442 (ER)
Wires and cables shall be so placed and protected as
3.10.1.2 Protection.
to avoid contact with rough or irregular surfaces or sharp edges. Wires shall
not be bent sharply where they enter insulation material.
3.10.1.3 Splicing.
Wires in a continuous run between two terminals shall not
All ground wires must be trunk tapped,
be spliced during the wiring operation.
not daisy chained.
Wiring shall be identified by color coding
3.10.1.4 Identification of wiring.
and wire pair marking as defined on the drawings.
3.10.2
Finish, protective.
Equipment shall be given protective finish in
accordance with MIL-F-14072. This includes finish of hardware and touch-up
after mounting and installation, as specified in 3.10.2.1 and 3.10.2.2.
Touch-up and finish of the shelter exterior paint
3.10.2.1 Shelter Exterior.
snail be in accordance with P515 of MIL-F-14072 followed with an application of
lusterless olive drab per MIL-C-46168.
3.10.2.2 Shelter Interior.
Shelter touch-up paint, where required, shall be in
accordance with P513 of MIL-F-14072, followed with an application as listed below
where required:
Ceiling:
White Epoxy Paint per MIL-C-22750
a.
Door and door brace:
Same as 3.10.2.1 to match exterior.
b.
Lined with corrosion resistant formica, design 360, 30
Walls:
c.
Avocado Gossimar, or equal.
finish, color:
d.
Floor:
Covered with corrosion resistant linoleum floor covering,
Armstrong Vinyl Corlon, Polestra, Catalog #86367 or equal.
3.10.3
Marking
For the purpose of marking, the equipment
Marking shall conform to MIL-M-13231.
shall be considered air-transportable and air mobile.
Wherever practical, parts shall be so mounted that their identification markings
will be readily visible with minimum disassembly of the equipment.
Cleaning.
3.10.4
After fabrication, parts shall be cleaned in accordance with
3.10.4.1 Parts.
good commercial practice or as specified in drawings. Cleaning process shall have
Corrosive material shall be removed completely before the
no deleterious effect.
parts are mounted.
3.10.4.2 Units. After assembly. the equipment shall be cleaned thoroughly
and shall be free from excess solder or flux, loose hardware and other foreign
material.