MIL-H-45193D
*
4.4.2 Sampling. Sampling for quality conformance inspection shall in
conformance with MIL-STD-105 using the following inspection Levels and Acceptable
Quality Levels (AQL):
Inspection or test
Level
AQL
Product examination (see 4.5)
II
1.0
Tests (see 4.6.1 and 4.6.3)
II
1.0
Packaging inspection (see 4.7)
S-4
4.0
*
4.5 Product examination. The heater guns shall be examined to determine
compliance with the requirements of Section 3 and the contract. As a minimum, the
following characteristics shall be examined:
REQUIREMENT
PARAGRAPH
CHARACTERISTICS
Design
3.2
Material
3.3
Reclaimed materials when applicable
3.3.1
3.4
Construction
Castings and forgings
3.4.1
Welding, brazing and soldering
3.4.2
Fastening devices
3.4.3
Electrical connections
3.4.4
Threads
3.4.5
Safety provisions
3.4.6
3.4.6.1
Underwriter's Laboratories approval
Interchangeability
3.4.7
3.4.8
Surfaces
Performance and product characteristics
3.5
Operational cycle
3.5.1
Temperature stability
3.5.2
Dielectric strength
3.5.3
Physical dimensions
3.5.4
3.6
Components
Body and handle
3,6.1
Protective screen
3.6.1.1
Electrical equipment
3.6.2
Blower and motor
3.6.2.1
Temperature rise
3.6.2.2
Electric control switch
3.6.2.3
Power supply cord
3.6.2.4
Air regulator
3.6.3
Heat reflectors
3.6.4
Product identification
3.7
Workmanship
3.8
A certificate of conformance may be provided to satisfy the examination
requirement where more than a visual or dimensional verification is necessary.
4.6 Tests.
*
4.6.1 Performance test. The performance test shall be conducted in an
ambient temperature of +75°F ±5°F. After operating the heater for at least 30
minutes with the heater gun on and blowing heated air at the maximum setting, the
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business